RENTAL RATES:
$20 – 4 hours | $30 – day | $120 – week
- Five programmable memories
- PLC control automation, or optional USB interface
- Advanced security settings
- Milliohm offset function for accurate ground bond testing
- Redundant hardware safety interlock
- Portable, rugged design
| Manufacturer Specs INPUT Voltage: 264: 100 – 120 VAC / 200 – 240 VAC ± 10% Auto Range 266: 100 – 240 VAC ± 10% Full Range Frequency: 50/60 Hz ± 5% Fuse 264 10A / 250 VAC Slow-Blow 266 15A / 250 VAC Slow-Blow GROUND BOND TEST MODE Output Rating: 264: 3.0 – 40.0 AAC 266: 3.0 – 60.0 AAC Resolution: 0.1 A Regulation: ± (2% of setting + 0.1A) 264: Voltage 6 VAC (fixed) 266: Voltage 12 VAC (fixed) Output Frequency 50/60 Hz user selectable Accuracy: ± 0.1% Resistance Limit Settings 264: 0 – 150 mΩ for 30.1 – 40.0 A 0 – 200 mΩ for 10.1 – 30.0 A 0 – 600 mΩ for 3.0 – 10.0 A 266: 0 – 150 mΩ for 30.1 – 60.0 A 0 – 200 mΩ for 15.1 – 30.0 A 0 – 600 mΩ for 3.0 – 15.0 A Resolution: 1 mΩ Accuracy: ± (2% of setting + 2 mΩ) Offset Limit Settings 0 – 100 mΩ Resolution: 1 mΩ Accuracy: ± (2% of setting + 2 mΩ) Dwell Timer 0, 0.5 – 240.0 sec, (0=continuous), 0.1 sec/step Ramp Timer 0.1 sec fixed Measurement Current 264: 0.0 – 40.0 AAC 266: 0.0 – 60.0 AAC Resolution: 0.1 A Accuracy: ± (3% of reading + 0.1 A) Ohmmeter 264 0 – 600 mΩ Resolution: 1 mΩ Accuracy: ± (3% of reading + 3 mΩ) for 3 – 5.9 A 266 0 – 600 mΩ Resolution: 1 mΩ Accuracy: ± (3% of reading + 3 mΩ) for 3 – 5.9 A (2% of reading + 2 mΩ) for 6 – 40 A | GENERAL SPECIFICATIONS Memories 5 Remote I/O Input: Test, Reset, Interlock Output: Pass, Fail, Test-in-Process Hardware Interlock – a relay on the high voltage output opens when the Interlock signal is disabled. Voltage Drop Display (optional) Display the voltage drop across the circuit instead of the resistance measurement. Voltage Limit Settings 264 0.00 – 6.00 VAC 266 0.00 – 9.00 VAC Resolution: 0.01 V Accuracy: ± (2% of setting + 0.02 V) Offset Limit Settings 264 0.00 – 4.00 VAC 266 0.00 – 6.00 VAC Resolution: 0.01 V Accuracy: ± (2% of setting + 0.02 V) Security Option to turn On or Off, when On you can switch between two security levels: 1. Run – Operator can only run a test. No ability to change memory locations or edit test parameters. 2. Mem – Operator can run a test and change memory locations. No ability to edit test parameters. Safety Mark CE/cTUVus Dimensions (W x H x D) 264 8.5″ x 3.5″ x 11.81″ (215 x 88 x 300 mm) 266 16.93″ x 5.20″ x 11.81″ (430 x 132 x 300 mm) Weight 264 9.25 lbs. (4.2 Kg) 266 20.25 lbs. (9.2 Kg) Tech Specs Safety Testing / Surge Testing/Ground Bond Testers Template Test Method (Safety) IEC 61010-1 Maximum Test Current 60 A Resolution AC Current 0.1 A Adjustable Test Current (Ground Bond): Yes Programmable: No Display Type: Digital Graphical Display: No Measurement Method (Ground Bond) |